CVE-2026-111497
Attackers are using this.
CISA added it to its list of vulnerabilities being exploited on October 27, 2026.
CISA's advice: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
What it is
A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
What it affects, and the version that fixes it
- .NET Make sure you are on 10.0.14 or later.
- Debian No fixed version listed yet.
- 7-Zip p7zip No fixed version listed yet.
- Andy Balholm (andybalholm) Brotli Make sure you are on 1.2.7 or later.
- Anthropic Bun Make sure you are on 1.4.4 or later.
- Apache Software Foundation Arrow No fixed version listed yet.
- ClickHouse No fixed version listed yet.
- DuckDB No fixed version listed yet.
- Envoy Proxy Envoy Make sure you are on 1.39.3 or later.
- Google Brotli Make sure you are on 1.2.1 or later.
- Google WOFF2 No fixed version listed yet.
- Istio Make sure you are on 1.31.2 or later.
- Mcmilk 7-Zip-zstd (7-Zip ZS) No fixed version listed yet.
- Nodejs Node.js Make sure you are on 26.12.1 or later.
- Python-hyper BrotliCFFI Make sure you are on 1.2.1.0 or later.
- Siemens Common Configurator No fixed version listed yet.
- Siemens COMOS Walkinside No fixed version listed yet.
- Siemens Data Flow Monitoring (DFM) Make sure you are on 3.0.18 or later.
- Siemens DataXess Configurator Make sure you are on 1.5.7 or later.
- Siemens Edge OPC UA Server Configurator Make sure you are on 2.3.10 or later.
- Siemens Flow Creator Configurator Make sure you are on 1.15.1 or later.
- Siemens HyperLynx No fixed version listed yet.
- Siemens Industrial Edge Cloud Connector Configurator Make sure you are on 1.24.3 or later.
- Siemens Industrial Edge Databus Configurator Make sure you are on 4.0.1 or later.
- Siemens Industrial Edge Hub No fixed version listed yet.