CVE-2024-8957
Attackers are using this
High severity
Published September 17, 2024
· updated June 17, 2026
Attackers are using this.
CISA added it to its list of vulnerabilities being exploited on November 4, 2024.
CISA's advice: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
What it is
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
What it affects, and the version that fixes it
- PTZOptics PT30X-NDI-XX-G2 Firmware Make sure you are on 6.3.40 or later.
- PTZOptics PT30X-SDI Firmware Make sure you are on 6.3.40 or later.