CVE-2024-8956
Attackers are using this.
CISA added it to its list of vulnerabilities being exploited on November 4, 2024.
CISA's advice: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
What it is
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
What it affects, and the version that fixes it
- PTZOptics PT30X-NDI-XX-G2 Firmware Make sure you are on 6.3.40 or later.
- PTZOptics PT30X-SDI Firmware Make sure you are on 6.3.40 or later.