CVE-2017-5689

Attackers are using this Critical severity Published May 2, 2017 · updated June 17, 2026

Attackers are using this.

CISA added it to its list of vulnerabilities being exploited on January 28, 2022.

CISA's advice: Apply updates per vendor instructions.

What it is

An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).

What it affects, and the version that fixes it

  • Hpe Proliant Ml10 Gen9 Server Firmware No fixed version listed yet.
  • Intel Active Management Technology (AMT) Firmware No fixed version listed yet.
  • Siemens SIMATIC FIELD PG M3 Firmware Make sure you are on 6.2.61.3535 or later.
  • Siemens SIMATIC FIELD PG M4 Firmware Make sure you are on 18.01.06 or later.
  • Siemens Simatic Field PG M5 Firmware Make sure you are on 22.01.03 or later.
  • Siemens SIMATIC IPC427D Firmware No fixed version listed yet.
  • Siemens SIMATIC IPC427E Firmware Make sure you are on 21.01.05 or later.
  • Siemens SIMATIC IPC477D Firmware No fixed version listed yet.
  • Siemens SIMATIC IPC477E Firmware Make sure you are on 21.01.05 or later.
  • Siemens SIMATIC IPC547D Firmware Make sure you are on 7.1.91.3272 or later.
  • Siemens SIMATIC IPC547E Firmware Make sure you are on 9.1.41.3024 or later.
  • Siemens SIMATIC IPC547G FIRMWARE Make sure you are on 11.0.26.3000 or later.
  • Siemens SIMATIC IPC627C Firmware Make sure you are on 6.2.61.3535 or later.
  • Siemens SIMATIC IPC627D Firmware Make sure you are on 9.1.41.3024 or later.
  • Siemens SIMATIC IPC647C Firmware Make sure you are on 6.2.61.3535 or later.
  • Siemens SIMATIC IPC647D Firmware Make sure you are on 9.1.41.3024 or later.
  • Siemens SIMATIC IPC677C Firmware Make sure you are on 6.2.61.3535 or later.
  • Siemens SIMATIC IPC677D Firmware Make sure you are on 9.1.41.3024 or later.
  • Siemens SIMATIC IPC827C Firmware Make sure you are on 6.2.61.3535 or later.
  • Siemens SIMATIC IPC827D Firmware Make sure you are on 9.1.41.3024 or later.
  • Siemens SIMATIC IPC847C Firmware Make sure you are on 6.2.61.3535 or later.
  • Siemens SIMATIC IPC847D Firmware Make sure you are on 9.1.41.3024 or later.
  • Siemens SIMATIC ITP1000 Firmware Make sure you are on 9.1.41.3024 or later.
  • Siemens SIMATIC PCS 7 IPC427E Firmware Make sure you are on 21.01.04 or later.
  • Siemens SIMATIC PCS 7 IPC477DFirmware No fixed version listed yet.

The vendor's advice · The official record (NVD) · CVE.org