CVE-2014-0160
Attackers are using this
High severity
Published April 7, 2014
· updated June 17, 2026
Attackers are using this.
CISA added it to its list of vulnerabilities being exploited on May 4, 2022.
CISA's advice: Apply updates per vendor instructions.
What it is
The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug.
What it affects, and the version that fixes it
- Debian No fixed version listed yet.
- OpenSSL Make sure you are on 1.0.1g or later.
- Ubuntu No fixed version listed yet.
- Broadcom Symantec Messaging Gateway (SMG) No fixed version listed yet.
- Fedora No fixed version listed yet.
- FileZilla-project FileZilla Server Make sure you are on 0.9.44 or later.
- Intellian v100 Firmware No fixed version listed yet.
- Intellian v60 Firmware No fixed version listed yet.
- Mitel MiCollab No fixed version listed yet.
- Mitel MiVoice No fixed version listed yet.
- OpenSUSE No fixed version listed yet.
- Red Hat Enterprise Linux Server No fixed version listed yet.
- Red Hat Enterprise Linux Server (TUS) No fixed version listed yet.
- Red Hat Enterprise Linux Server Advanced mission critical Update Support (AUS) No fixed version listed yet.
- Red Hat Enterprise Linux Server Extended Update Support (EUS) No fixed version listed yet.
- Red Hat Enterprise Linux Workstation No fixed version listed yet.
- Red Hat Gluster Storage No fixed version listed yet.
- Red Hat Storage No fixed version listed yet.
- Red Hat Virtualization No fixed version listed yet.
- Redhat Enterprise Linux Desktop No fixed version listed yet.
- Ricon S9922l Firmware No fixed version listed yet.
- Siemens Application Processing Engine (APE) Firmware No fixed version listed yet.
- Siemens CP 1543-1 Firmware No fixed version listed yet.
- Siemens eLAN-8.2 Make sure you are on 8.3.3 or later.
- Siemens SIMATIC S7-1500 Firmware No fixed version listed yet.